GENERAL INFORMATION FOR METAL
TABLES
MOTORS
Motors are totally enclose
fan cooled (TEFC). Hazardous location motors are available upon request. These
motors will have the mag. starters and timers but they will not be mounted on
the machine. The buyer must mount the switches on the wall at the distance
allowed by OSHA or their insurance company. If the buyer wants the switches
mounted on the machines, we must have it in writing that that they understand
that these machines are not to be set in a location where hazardous fumes are
present.
RECEPTACLES
Receptacles are only standard
on the 3646BG single phase machine. They may be ordered for the other machines.
On any three-phase machines, single-phase power must be brought to machines for
the receptacles. If you feel that receptacles are important for your machine,
figure the location for them and have the receptacles installed at the factory.
CASTERS
Casters are standard on the
3646BG table. Casters may be installed on the other machines but they will alter
the height some. Casters must be installed at the factory; they are not an after
market item.
WORK SURFACE
Work surface is standard 1”
grate 35 lbs. per square foot. Heavier grate and fiberglass grate
is available if needed. A removable rubber pad for the steel grate is also
available for protecting polished products.
EXHAUST CHIMNEY
The chimneys on DENRAY’s
machines are located on the end of the machine and are a standard feature on
models 9600BG and 7200BG. Without a chimney the exhaust may be too much air for
the surrounding environment. Chimneys are optional on the 2872BG and the 3644BG
tables.
WATER PANS
Water pans force the grit and
sparks to cross the water before entering flame retardant filters. This system
will help prevent any hot slag from entering the filter compartment. It would
also be a great asset when plasma cutting.
CENTRAL SYSTEM UNITS
Although DENRAY’s main
focus is on self-contained units we also build, on special order, non-motorized
units for central systems. These units are built to meet your needs. They
contain inside deflectors to prevent the majority of the grit and sparks from
entering the vacuum system. Water pans are available as an option.
SPARK SHIELDS
The table is provided with a
20” tall shield around the work area. These shields are hinged and removable to
accommodate larger or longer work pieces. These are designed to increase the
efficiency of the table and to protect co-workers, bystanders, and the work
area. These may also be altered to fit the users needs
Informative video available upon request
|